tissue level implant
simple line

SIMPLE LINE II

OVERCOME DEMERITS OF EXISTING ONE-STAGE
SURGERY THROUGH

• Maximised depth of the octagon design to enable easy adaptation verification for dual abutment application
• Offers additional gingival height options (SCA abutment)
• Double-threaded design minimises chair time
• Minimised risk of resin falling apart through sufficient
attachment space

SIMPLE LINE II

OVERCOME DEMERITS OF EXISTING ONE-STAGE SURGERY THROUGH

• Maximised depth of the octagon design to enable easy adaptation verification for dual abutment application
• Offers additional gingival height options (SCA abutment)
• Double-threaded design minimises chair time
• Minimised risk of resin falling apart through sufficient attachment space

simple line
simple line

SIMPLE LINE II

COLOR CODING BY DIAMETER

implant sydney

SIMPLE LINE II

COLOR CODING BY DIAMETER

implant sydney
simpleline-dentium-minimax-implant-900x400-0000

SIMPLE LINE II

SCA Abutment

• Offers additional gingival height options
• Implantation with the SCA Abutment
• Able to reproduce emergence profile
• Effective soft tissue management

simpleline-dentium-minimax-implant-900x400-0000

SCA Abutment

• Offers additional gingival height options
• Implantation with the SCA Abutment
• Able to reproduce emergence profile
• Effective soft tissue management

simpleline-dentium-minimax-implant-900x400-0000

SIMPLE LINE II

Tap Drill

• Tap drills for exquisite surgery to enable early loading
• Smooth and precise surgery with tap drill in type 1~3 bone. · 4mm of tapping depth for optimum torque control

simpleline-dentium-minimax-implant-900x400-0000

Tap Drill

• Tap drills for exquisite surgery to enable early loading
• Smooth and precise surgery with tap drill in type 1~3 bone. · 4mm of tapping depth for optimum torque control

simpleline-dentium-minimax-implant-900x400-03

Internal 8° Morse Taper and Octagon

• Screw loosening is well prevented due to the cold welding mechanism for solid abutment application
• Maximised depth of the octagon design to enable easy adaptation verification for dual abutment application

simpleline-dentium-minimax-implant-900x400-03

SIMPLE LINE II

Internal 8° Morse Taper
and Octagon

• Screw loosening is well prevented due to the cold welding mechanism for solid abutment application
• Maximised depth of the octagon design to enable easy adaptation verification for dual abutment application

simpleline-dentium-minimax-implant-900x400-03

SIMPLE LINE II

Double Thread & Thread Height

• Sharp edged and high density threads allows fasts and successful osseointegration
• Double-threaded design minimises chair time

simpleline-dentium-minimax-implant-900x400-03

Double Thread & Thread Height

• Sharp edged and high density threads allows fasts and successful osseointegration
• Double-threaded design minimises chair time

simpleline-dentium-minimax-implant-900x400-03

SIMPLE LINE II

Tilting Angle

• Able to accommodate occlusion with ease
• Minimised risk of resin falling apart through sufficient attachment space

simpleline-dentium-minimax-implant-900x400-03

Tilting Angle

• Able to accommodate occlusion with ease
• Minimised risk of resin falling apart through sufficient attachment space

simpleline-dentium-minimax-implant-900x400-03

SIMPLE LINE II

Osseointegration

• The greater distance between the threads may promote early osseointegration

simpleline-dentium-minimax-implant-900x400-03

Osseointegration

• The greater distance between the threads may promote early osseointegration

VOD

DENTIUM SIMPLE LINE II

VOD

DENTIUM SIMPLE LINE II